HPDE.io SPASE landing pages.

Ulysses Cosmic Ray and Solar Particle Investigation (COSPIN) High Energy Telescope (HET) Full Resolution Housekeeping Parameters, 256 s Data

ResourceID
spase://NASA/NumericalData/Ulysses/COSPIN/HET/Housekeeping/PT256S

Description

A Directory containing Daily FTP downloadable Files containing Readout-by-Readout Listings of HET Housekeeping Parameters (Voltages, Temperatures, Offsets). The Naming Convention of the Files is uly_het_full_house_YYYDDD.txt, where YYY indicates the three digit Year since 1900 (e.g. YYY=090 for 1990, and YYY=102 for 2002) and DDD indicates the three digit Day of Year (January 1 = 1). In each File, following a detailed Description of the Format, the Data consist of a Listing of HET Housekeeping Parameters measured at the Time listed in the first four Columns of each Line. Each Line contains Data for one Readout of the Parameters. The first four Columns give the Time of the Measurement as Fractional Year (to 12 Decimal Places) and as Year since 1900, Day of Year, and Milliseconds of Day. At the most common Science Telemetry Rate, 2048 bps, each Parameter in this File is Readout once every 256 s. The Measurements are instantaneous, and do not represent an Average of Values over the Interval since the last Readout. The sole Function of these Parameters is to monitor Instrument Health. No Noise Removal or Despiking has been done, so Caution must be used in interpreting isolated large Increases or Decreases in the measured Parameters.

View XML | View JSON | Edit

Details

Version:2.2.9

NumericalData

ResourceID
spase://NASA/NumericalData/Ulysses/COSPIN/HET/Housekeeping/PT256S
ResourceHeader
ResourceName
Ulysses Cosmic Ray and Solar Particle Investigation (COSPIN) High Energy Telescope (HET) Full Resolution Housekeeping Parameters, 256 s Data
ReleaseDate
2020-07-07 21:15:39Z
Description

A Directory containing Daily FTP downloadable Files containing Readout-by-Readout Listings of HET Housekeeping Parameters (Voltages, Temperatures, Offsets). The Naming Convention of the Files is uly_het_full_house_YYYDDD.txt, where YYY indicates the three digit Year since 1900 (e.g. YYY=090 for 1990, and YYY=102 for 2002) and DDD indicates the three digit Day of Year (January 1 = 1). In each File, following a detailed Description of the Format, the Data consist of a Listing of HET Housekeeping Parameters measured at the Time listed in the first four Columns of each Line. Each Line contains Data for one Readout of the Parameters. The first four Columns give the Time of the Measurement as Fractional Year (to 12 Decimal Places) and as Year since 1900, Day of Year, and Milliseconds of Day. At the most common Science Telemetry Rate, 2048 bps, each Parameter in this File is Readout once every 256 s. The Measurements are instantaneous, and do not represent an Average of Values over the Interval since the last Readout. The sole Function of these Parameters is to monitor Instrument Health. No Noise Removal or Despiking has been done, so Caution must be used in interpreting isolated large Increases or Decreases in the measured Parameters.

Acknowledgement
Please acknowledge the COSPIN HET Lead Investigator and COSPIN PI, R. Bruce McKibben
Contacts
RolePersonStartDateStopDateNote
1.PrincipalInvestigator
TeamLeader
spase://SMWG/Person/R.Bruce.McKibben
2.DataProducerspase://SMWG/Person/Clifford.Lopate
3.CoInvestigatorspase://SMWG/Person/James.Connell
InformationURL
Name
The Ulysses Cosmic Ray and Solar Particle Investigation, COSPIN
URL
Description

Published Description of the COSPIN Instrumentation, J.A. Simpson et al., Astron. Astrophys. Suppl. Ser. 92, 365-399, 1992. See especially Section 4.3 for a detailed Description of the High Energy Telescopes, HET. An electronic Copy of this Paper is available at http://adsbit.harvard.edu/cgi-bin/nph-iarticle_query?1992A%26AS...92..365S&defaultprint=YES&filetype=.pdf.

InformationURL
Name
User Notes for the COSPIN/HET Data Files
URL
Description

The User Notes File at the Ulysses Final Archive (UFA) describes the Format of the ASCII Data Files for the COSPIN High Energy Telescope, HET

InformationURL
Name
COSPIN HET Full Resolution ReadMe Document, Word Format
URL
Description

Top Level Descriptions of Formats and Contents of the six File Types that make up the COSPIN HET Full Resolution Data Set. Detailed Descriptions of the Formats and Contents are found in Header Lines at the Start of each downloaded Data File. The Data covered by this SPASE Description are described in the ReadMe under the Heading House. (*** Note ***: During the Build-up of this Data Set, a few Errors and Omissions have been found in the Header Lines for some of the File Types. These Errors and Omissions are listed in this ReadMe File. Upon Completion of the Data Set, all Errors and Omissions discovered will be corrected in all of the Header Lines of all of the File Types at which time this Note will be removed).

PriorIDs
spase://VEPO/NumericalData/Ulysses/COSPIN/HET/FullResolution/House
spase://VSPO/NumericalData/Ulysses/COSPIN/HET/Housekeeping/PT256S
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
Ulysses Final Archive Access to COSPIN/HET Full Resolution Housekeeping Parameters
URL
Description

Parent Directory containing FTP downloadable Daily Files with the Format described below

Format
Text
Encoding
ASCII
Acknowledgement
Please acknowledge R. Bruce McKibben, Space Science Center, University of New Hampshire
InstrumentIDs
MeasurementType
InstrumentStatus
TemporalDescription
TimeSpan
StartDate
1990-10-22 00:00:00.000
StopDate
2009-06-29 23:59:59.999
Cadence
PT256S
ObservedRegion
Heliosphere.Outer
Parameter #1
Name
Time of Measurement
Description

Time at which the Measurements were made

Cadence
PT256S
Structure
Size
4
Element
Name
Decimal Year
Index
1
ParameterKey
Column_1
ValidMin
1990
ValidMax
2009
FillValue
0.00000000000
Element
Name
Year
Index
2
ParameterKey
Column_2
ValidMin
1990
ValidMax
2009
FillValue
0
Element
Name
Day of Year
Index
3
ParameterKey
Column_3
ValidMin
1
ValidMax
366
FillValue
0
Element
Name
Milliseconds of Day
Index
4
ParameterKey
Column_4
ValidMin
0
ValidMax
86400000
FillValue
0
Support
SupportQuantity
Temporal
Parameter #2
Name
ADC Offset
ParameterKey
Column_5
Description

Offset of Analogue to Digital Converter Base from Zero Volts

Caveats
During In-Flight-Calibrate Sequences, the ADC Offset Measurement is disabled and is replaced in the Telemetry by the +15 V Monitor Measurement. During these Times, the ADC Offset Measurement in this Listing is replaced by fill.
Cadence
PT256S
Units
mV
ValidMin
-9600
ValidMax
3200
FillValue
-99999
Support
SupportQuantity
Other
Parameter #3
Name
COSPIN/HET +15 V Monitor
ParameterKey
Column_6
Description

Measurement of the Voltage on the +15 V regulated Power Line from the COSPIN Converter.

Caveats
This Measurement is reported only during In-Flight-Calibrate Sequences. At all other Times it is represented in this Listing by fill.
Cadence
PT256S
Units
mV
ValidMin
0
ValidMax
18750
FillValue
-99999
Support
SupportQuantity
Other
Parameter #4
Name
COSPIN/HET +10 V Monitor
ParameterKey
Column_7
Description

Measurement of the Voltage on the +10 V Line from the COSPIN Converter.

Caveats
None
Cadence
PT256S
Units
mV
ValidMin
0
ValidMax
12700
FillValue
-99999
Support
SupportQuantity
Other
Parameter #5
Name
COSPIN/HET -6 V Monitor
ParameterKey
Column_8
Description

Measurement of the Voltage on the -6 V Line from the COSPIN Converter.

Caveats
None
Cadence
PT256S
Units
mV
ValidMin
-7700
ValidMax
0
FillValue
-99999
Support
SupportQuantity
Other
Parameter #6
Name
COSPIN/HET -15 V Monitor
ParameterKey
Column_9
Description

Measurement of the Voltage on the -15 V Line from the COSPIN Converter.

Caveats
None
Cadence
PT256S
Units
mV
ValidMin
-19000
ValidMax
0
FillValue
-99999
Support
SupportQuantity
Other
Parameter #7
Name
COSPIN/HET PMT Voltage
ParameterKey
Column_10
Description

Operating Voltage of the PMT viewing the HET Anti-Coincidence Cylinder.

Caveats
None
Cadence
PT256S
ValidMin
0
ValidMax
1275000
FillValue
-9999
Support
SupportQuantity
Other
Parameter #8
Name
COSPIN/HET K1 Voltage
ParameterKey
Column_11
Description

Bias Voltage for Detectors KX,KY,KZ (DX,DY,DZ). Documentation available in 2009 does not make clear whether the Detectors were K1,K2,K3 (D7,D8,D9) or K4,K5,K6 (D10,D11,D12).

Caveats
None
Cadence
PT256S
Units
mV
ValidMin
0.0
ValidMax
1020000
FillValue
-9999
Support
SupportQuantity
Other
Parameter #9
Name
COSPIN/HET K2 Voltage
ParameterKey
Column_12
Description

Bias Voltage for Detectors KA,KB,KC (DA,DB,DC). Documentation available in 2009 does not make clear whether the Detectors were K1,K2,K3 (D7,D8,D9) or K4,K5,K6 (D10,D11,D12).

Caveats
None
Cadence
PT256S
Units
mV
ValidMin
0.0
ValidMax
1020000
FillValue
-9999
Support
SupportQuantity
Other
Parameter #10
Name
COSPIN/HET Electronics Temperature
ParameterKey
Column_13
Description

Temperature of the HET Electronics.

Caveats
None
Cadence
PT256S
Units
1000 °
ValidMin
-60000
ValidMax
70000
FillValue
-99999
Support
SupportQuantity
Other